Title page for etd-1231117-172751


URN etd-1231117-172751 Statistics This thesis had been viewed 350 times. Download 1 times.
Author Yueh-Dung Huang
Author's Email Address No Public.
Department Department of construction & spatial design
Year 2017 Semester 1
Degree Master Type of Document Master's Thesis
Language zh-TW.Big5 Chinese Page Count 119
Title Effect of vibration on A.C. impedance property of reinforcement concrete
Keyword
  • A.C. impedance
  • reinforcement concrete
  • cement paste
  • water-cement ratio
  • equivalent circuit
  • equivalent circuit
  • water-cement ratio
  • cement paste
  • reinforcement concrete
  • A.C. impedance
  • Abstract This paper is to study different water-cement ratio¡¦s reinforcement concrete by vibration to impedance property¡¦s effect and change, and using equivalent circuit plot simulation to analyze A.C. impedance.
    The research conclusion shows, vibrate age of cement in 2 hours of ratio water-cement 0.34, impedance data value in frequency when it at 1,000 Hz it will change from 16.65 £[ into 16.84 £[, impedance data value become higher through vibration. Vibrate age of cement in 3 days of ratio water-cement 0.34 and 0.37 and 0.40, impedance data value in frequency when it at 1,000 Hz it will change from 197.08 £[ into 193.52 £[ of ratio water-cement 0.34, impedance data value in frequency when it at 1,000 Hz it will change from 184.25 £[ into 180.80 £[ of ratio water-cement 0.37, impedance data value in frequency when it at 1,000 Hz it will change from 208.45 £[ into 205.99 £[ of ratio water-cement 0.40, impedance data value all become lower through vibration. Vibrate age of cement in 2 hours of ratio water-cement 0.37, impedance data value in frequency when it at 1,000 Hz it will change from 16.86 £[ into 15.59 £[, impedance data value become lower through vibration. Vibrate age of cement in initial set plus 30 minutes of ratio water-cement 0.37, impedance data value in frequency when it at 1,000 Hz it will change from 18.06 £[ into 15.88 £[, impedance data value become lower through vibration.
    By equivalent circuit plot simulation, 0.34 water-cement ratio, the analysis of equivalent circuit model with interface effect is more accurate than that without interface effect.
    Advisor Committee
  • Ping-Ju Lin - advisor
  • none - co-chair
  • none - chair
  • Files indicate in-campus access immediately and off-campus access at 1 years
    Date of Defense 2017-12-27 Date of Submission 2018-01-03