Title page for etd-0114121-230533


URN etd-0114121-230533 Statistics This thesis had been viewed 90 times. Download 1 times.
Author Chih-Chieh Huang
Author's Email Address No Public.
Department Department of construction & spatial design
Year 2020 Semester 1
Degree Master Type of Document Master's Thesis
Language zh-TW.Big5 Chinese Page Count 67
Title Discussion on the Exhaust Performance of Automatic Exhaust Fan
Keyword
  • automatic exhaust fan
  • automatic exhaust system
  • automatic exhaust system
  • automatic exhaust fan
  • Abstract In recent years, fires have spread frequently, causing many casualties. According to the statistics of the Fire Department of the Ministry of the Interior, dense smoke ranks among the top three causes of fire deaths in the past two years. Among them, taking 108 as an example, the number of fires reached 22,866. Building fires occurred the most, and residential fires occurred the most. Among them, stove cooking and electrical factors occurred the highest, while building fires were the most frequent The kitchen, bedroom, and living room have a high frequency of occurrence, and harmful gases are the first cause of death due to heavy smoke in 108 years, and flame burning is the second.
      The automatic smoke exhaust fan is an independent item. Compare its advantages and disadvantages with the systematic smoke exhaust equipment, such as operating time, air volume, price, public acceptance, etc., to explore the practicality of the product after its release.
      The conclusions of this study are as follows: (1) The automatic smoke exhaust fan can operate within 30 seconds of the time specified by the smoke exhaust equipment, and it will exert its effect in the initial stage of the fire. (2) The greater the temperature difference of the automatic exhaust fan, the faster the action. (3) The exhaust air volume of the automatic exhaust fan is reversed according to the air volume specified by the exhaust equipment, which can protect a room of about 20 square meters. (4) The air volume of the automatic exhaust fan is fixed, and there is no obvious difference between each test. (5) There are almost no fire-fighting and smoke-exhausting equipment in people's homes. (6) The survey results found that nearly 90% of people are willing to install automatic smoke exhaust fans. (7) People who do not have simple fire-fighting equipment at home would not want to install an automatic smoke exhaust fan.
    Keywords: automatic exhaust fan, automatic exhaust system
    Advisor Committee
  • Jia-Chong Du - advisor
  • LI,Cheng-Xiao - co-chair
  • Zhao-Lin Zheng - co-chair
  • Files indicate access worldwide
    Date of Defense 2020-12-25 Date of Submission 2021-01-14

    Browse | All Available ETDs | Chinese Search Version | Home

    If you have more questions or technical problems, please contact Tungnan University